11
Start Reference Check
Before starting some grade work which is very sensitive an additional Reference Check can
bestartedmanually.Press and release the MENU button at the StandardDisplayandselect
ReferenceCheck.
Pressing and releasing button 4startstheReferenceCheckconsideringthecurrenttemperature
insidethehousing.Whiletherotorchecksthecorrectpositiontherotationwillbestopped.
Centering the Rotor
PressandreleasetheMENUbuttonattheStandardDisplayandselectCenteringwheretherotor
willbecentered90°perpendiculartothebottomhousing.
Pressing and releasing button 4 starts the rotor centering function while the rotor checks the
limitsofbothaxesthenitstopsatthecenterpositionandchangestheunitintomanualmode.
Setting Menu
PressandreleasetheMENUbuttonattheStandardDisplayandselectSettings.
Press and release button 4toopentheSettingMenu;selectthedesiredfunctionthenpressbutton
4toopentheselectedsubmenufunctionORstarttheselectedfunction.
PleaseseetheSettingMenudetailsattheendoftheuserguide.
Info
PressandreleasetheMENUbuttonattheStandardDisplayandselectInfo.
Buttons6/7canbeusedtotogglebetweenUL,RCandRuntime.
Press and release button 4toconrmtheselection.
TheUL/RCinformation(softwareversion,ID,etc.)ortheruntimeoftheULwillbedisplayed.
Service
PressandreleasetheMENUbuttonattheStandardDisplayandselectService.Buttons6/7 can be
used to toggle between Calibration Y and Calibration XOR Calibration Z when set up vertically.
Press and release button 4 to conrm the selection. The calibration at the selected axis starts the eld
calibration procedure.