Usebutton 1 or 2(PlusorMinus)tosetthedesireddigit.
Thelaserwillself-leveltotherequiredgradepositionafterconrmingthegradechangewithbutton4.
Note: Thebubblesymbolsatthelaser’sLCDwillashuntilthelaserhasbeenself-leveledtotherequested
grade position.
Using the Rotation mode
Repeatedlypressingthebutton4togglesthrough0,80,200,600,900rpmregardlessiftheunit
is in automatic or manual mode.
At0rpm,thebeamstopsautomaticallyclosetothe+Y-axiscenterposition(pipelayingover
the top).
Whensetuphorizontallyin automatic orgrademode,usingbuttons5/8increases/decreases
rotorspeedfrom0to80andthenupto900rpmcontinuouslyin10rpmincrements.
Pointing mode
At0rpm,buttons6/7movethebeamtotheleft/rightside.Whensetupverticallyat0rpm,button5/8 move
thebeamclockwise/counterclockwise.
Note: Press and hold button 4 for three seconds to change the unit from rotation mode (default) into scan mode.
Using the Scan mode
Press and hold button 4attheStandardDisplayforthreesecondstochangetheunitintoscan
mode.
Quickly press and release button 4totogglebetweenthepre-selectedscansizes5,15,45,90,
180degreesand0;regardlessiftheunitisinautomaticormanualmode.
Whenworkinginhorizontalautomaticmode,pressandholdbutton5/8toincrease/decreasethe
linesizein5degreesincrements.Pressandholdbutton 6/7movesthescanlinetotheright/leftdirection.
Whenusedinautomaticverticalmode,pressingandholdingbutton5/8movesthescanlinecounterclockwise/
clockwise.Whensetupvertical,pressingandholdingbutton6/7movesthescanlineintotheright/leftdirection
regardless if in automatic or manual mode.
Note: Press and hold button 4 for three seconds to change the unit back to rotation mode (default) mode.
Manual mode
Pressing and releasing button 3attheStandardDisplayactivates/deactivates
the manual mode regardless if set up horizontal or vertical.
Manual mode is indicated by horizontal lines next to the axes symbols.An
additionalbubblehelpstoadjustthelaseronthecrossaxiswhensetupvertical.
InManualmode(horizontal),theY-axiscanbeslopedbypressingtheUp-(5)andDown-Arrow-(8) buttons on
thelaser‘skeypadortheremotecontrol.Additionally,theX-axiscanbeslopedbypressingtheLeft-(6) and
Right-(7)Arrow-buttonsonthelaserorremotecontrol.
Inverticalmode,theupanddownarrowbuttonsadjusttheZ-axisslope,andtheleftandrightarrowbuttons
alignthelaserbeamtotheright/leftside.
To resume automatic self-leveling mode, press the manual button again.